Research on Lower Coherence Interferometer and corresponding optic fiber sensor
首发时间:2007-06-26
Abstract:Applying lower coherence interferometer executes scan of optic fiber sensor under different environmental state. Factors influence accuracy of results can be obtained through comparison between above tests, which are shown in details in this paper. Repeating test of optic fibers is completed as a part of calibration, an accuracy of 4 can be achieved as well. Data acquisition and data analysis are accomplished by the software of Labview. Installing reference point on signal arm to eliminate the deviation of initial scan time and reduce the error of lower coherence system.
keywords: optic fiber sensor, repeating test, Labview, reference point
点击查看论文中文信息
基金:
论文图表:
引用
No.1368648256118284****