Cost-effective sampling network design for contaminant plume monitoring under general hydrogeological conditions

吴剑锋Jianfeng Wuab Chunmiao Zhenga* Calvin C. Chienc

Journal of Contaminant Hydrology 77(2005)41-65,-0001,():

URL:

摘要/描述

A new simulation–optimization methodology is developed for cost-effective sampling network design associated with long-term monitoring of large-scale contaminant plumes. The new methodology is similar in concept to the one presented by Reed et al. (Reed, P.M., Minsker, B.S., Valocchi, A.J., 2000a. Cost-effective long-term groundwater monitoring design using a genetic algorithm and global mass interpolation. Water Resour. Res. 36 (12), 3731-3741) in that an optimization model based on a genetic algorithm is coupled with a flow and transport simulator and aglobal mass estimator to search for optimal sampling strategies. However, this study introduces the first and second moments of a three-dimensional contaminant plume as new constraints in the optimization formulation, and demonstrates the proposed methodology through a real-world application. The new moment constraints significantly increase the accuracy of the plume interpolated from the sampled data relative to the plume simulated by the transport model. The plume interpolation approaches employed in this study are ordinary kriging (OK) and inverse distance weighting (IDW). The proposed methodology is applied to the monitoring of plume evolution during a pump-and-treat operation at a large field site. It is shown that potential cost savings up to 65.6% may be achieved without any significant loss of accuracy in mass and moment estimations. The IDW-based interpolation method is computationally more efficient than the OKbased method and results in more potential cost savings. However, the OK-based method leads tomore accurate mass and moment estimations. A comparison of the sampling designs obtained with and without the moment constraints points to their importance in ensuring a robust long-term monitoring design that is both cost-effective and accurate in mass and moment estimations. Additional analysis demonstrates the sensitivity of the optimal sampling design to the various coefficients included in the objective function of the optimization model.

【免责声明】以下全部内容由[吴剑锋]上传于[2011年04月06日 15时31分42秒],版权归原创者所有。本文仅代表作者本人观点,与本网站无关。本网站对文中陈述、观点判断保持中立,不对所包含内容的准确性、可靠性或完整性提供任何明示或暗示的保证。请读者仅作参考,并请自行承担全部责任。

我要评论

全部评论 0

本学者其他成果

    同领域成果