您当前所在位置: 首页 > 学者

谢青季

  • 37浏览

  • 0点赞

  • 0收藏

  • 0分享

  • 138下载

  • 0评论

  • 引用

期刊论文

Scanning Electrochemical Microscopy in Combination with Piezoelectric Quartz Crystal Impedance Analysis for Studying the Growth and Electrochemistry as Well as Microetching of Poly(o-phenylenediamine) Thin Films

谢青季Xinman Tu † Qingji Xie *‡ Canhui Xiang ‡ Youyu Zhang † and Shouzhuo Yao†

J. Phys. Chem. B 2005, 109, 4053-4063,-0001,():

URL:

摘要/描述

ance (PQCI) analysis was proposed as a novel multiparameter method for investigating the cyclic voltammetric growth of poly(o-phenylenediamine) (PoPD) thin films at Au electrodes in aqueous solutions of various pH values and the potentiostatic microetching (localized degradation) of these films in 0.10mol/L aqueous H2-SO4 for comparative examinations on polymer porosity and stability. Two potential-sweep ranges, -0.4 to 0.9 (I) and 0 to 0.9 (II) V versus SCE, and four solutions, acidic (A, 0.20mol/L H2SO4 + 0.10mol/L Na2-SO4; B, 0.10 mol/L H2SO4+ 0.20mol/L Na2SO4), neutral (C, 0.10mol/L PBS + 0.20mol/L Na2SO4, pH 7.2), and alkaline (D, 0.20mol/L NaOH+ 0.20mol/L Na2SO4) aqueous solutions, were selected for PoPD growth. The pH increase for the polymerization solution increased the molar percentage of polyaniline-like chains in PoPD, as quantified from the current peaks at 0.6 V versus a saturated calomel electrode (SCE) for the oxidation of -NH2 groups in as-prepared PoPD (grown from solutions C and D) during their redox switching in 0.10mol/L aqueous H2SO4 for the first time. The unusual PQCI responses observed at negative potentials (potential range I) in the first several potential cycles during the cyclic voltammetric growth of PoPD in acidic and neutral solutions have been reasonably explained as being due to the precipitation/dissolution of the poorly soluble phenazinehydrine charge-transfer complexes developed during redox switching of oligomers for the first time, which brought about much less compact PoPD films and their higher degradability than those grown in the same solution but over potential range II. SECM, scanning electron microscopy (SEM), and piezoelectric quartz crystal (PQC) frequency were used to estimate the sizes of etched microscale spots. In addition, the x-, y-, or z-axis movement of a Pt microelectrode of 25-μm diameter near the PQC electrode was found to influence negligibly the PQCI responses in 1.0mol/L aqueous Na2SO4 containing K4Fe(CN)6 up to 0.10mol/L, and a new protocol of dynamically electrodepositing silver microwires via the chemical-lens method was proposed for examining the local mass-sensitivity distribution on the PQC surface.

关键词:

【免责声明】以下全部内容由[谢青季]上传于[2005年04月20日 22时17分16秒],版权归原创者所有。本文仅代表作者本人观点,与本网站无关。本网站对文中陈述、观点判断保持中立,不对所包含内容的准确性、可靠性或完整性提供任何明示或暗示的保证。请读者仅作参考,并请自行承担全部责任。

我要评论

全部评论 0

本学者其他成果

    同领域成果