您当前所在位置: 首页 > 学者

郑玉峰

  • 68浏览

  • 0点赞

  • 0收藏

  • 0分享

  • 91下载

  • 0评论

  • 引用

期刊论文

The development of binary MgeCa alloys for use as biodegradable materials within bone

郑玉峰Zijian Li ab Xunan Gu a Siquan Lou b Yufeng Zheng a*

Biomaterials 29(2008)1329-1344,-0001,():

URL:

摘要/描述

Binary MgeCa alloys with various Ca contents were fabricated under different working conditions. X-ray diffraction (XRD) analysis and optical microscopy observations showed that MgexCa (x ¼ 1e3 wt%) alloys were composed of two phases, a(Mg) and Mg2Ca. The results of tensile tests and in vitro corrosion tests indicated that the mechanical properties could be adjusted by controlling the Ca content and processing treatment. The yield strength (YS), ultimate tensile strength (UTS) and elongation decreased with increasing Ca content. The UTS and elongation of as-cast Mge1Ca alloy (71.38±3.01 MPa and 1.87±0.14%) were largely improved after hot rolling (166.7±3.01 MPa ±and 3±0.78%) and hot extrusion (239.63±7.21 MPa and 10.63±0.64%). The in vitro corrosion test in simulated body fluid (SBF) indicated that the microstructure and working history of MgexCa alloys strongly affected their corrosion behaviors. An increasing content of Mg2Ca phase led to a higher corrosion rate whereas hot rolling and hot extrusion could reduce it. The cytotoxicity evaluation using L-929 cells revealed that Mge1Ca alloy did not induce toxicity to cells, and the viability of cells for Mge1Ca alloy extraction medium was better than that of control. Moreover, Mge1Ca alloy pins, with commercial pure Ti pins as control, were implanted into the left and right rabbit femoral shafts, respectively, and observed for 1, 2 and 3 months. High activity of osteoblast and osteocytes were observed around the Mge1Ca alloy pins as shown by hematoxylin and eosin stained tissue sections. Radiographic examination revealed that the Mge1Ca alloy pins gradually degraded in vivo within 90 days and the newly formed bone was clearly seen at month 3. Both the in vitro and in vivo corrosion suggested that a mixture of Mg(OH)2 and hydroxyapatite formed on the surface of Mge1Ca alloy with the extension of immersion/implantation time. In addition, no significant difference (p>0.05) of serum magnesium was detected at different degradation stages. All these results revealed that Mge1Ca alloy had the acceptable biocompatibility as a new kind of biodegradable implant material. Based on the above results, a solid alloy/liquid solution interface model was also proposed to interpret the biocorrosion process and the associated hydroxyapatite mineralization.

【免责声明】以下全部内容由[郑玉峰]上传于[2010年01月25日 21时30分17秒],版权归原创者所有。本文仅代表作者本人观点,与本网站无关。本网站对文中陈述、观点判断保持中立,不对所包含内容的准确性、可靠性或完整性提供任何明示或暗示的保证。请读者仅作参考,并请自行承担全部责任。

我要评论

全部评论 0

本学者其他成果

    同领域成果