您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者10条结果 成果回收站

上传时间

2005年01月17日

【期刊论文】Deletion of two C-terminal Gln residues of 12-26-residue fragmentof melittin improves its antimicrobial activity

宓怀风, Xuejun Sun, Suxia Chen, Shunzi Li, Husheng Yan*, Yunge Fan, Huaifeng Mi

Peptides xxx (2004) xxx-xxx,-0001,():

-1年11月30日

摘要

In our previous paper it was shown that the two C-terminal Gln residues of a C-terminal 15-residue fragment, Mel(12-26)(GLPALISWIKRKRQQ-NH2), of melittin and a series of individual substituted analogues might not involved in the interaction withbacterial membranes. In this paper, peptides with one and two Gln residues deletion, respectively, Mel(12-25) and Mel(12-24), weresynthesized and characterized. Both of the deletion peptides showed higher antimicrobial activities than the parent peptide, Mel(12-26). If both of the Gln residues of Mel(12-26) were respectively replaced by a hydrophilic amino acid Gly, the antimicrobial activity increasedslightly. If the Gln residue of Mel(12-25) was replaced by a hydrophobic amino acid Leu, the antimicrobial activity changed little, althoughthe substituted peptide possessed much higher hydrophobicity and higher α-helical conformation percentage in 1,1,1,3,3,3-hexafluoro-2-propanol/water determined by circular dichroism spectroscopy (CD) than the parent peptide. These results indicated that the two C-terminalresidues might be indeed not involved in the binding to bacterial membranes. The antimicrobial activity increasing with the residue deletionmay be caused by the decrease of the translational and rotational entropic cost of the binding of the peptides to bacterial membranes becauseof the lower molecular weights of the deletion peptides.

Melittin, Antimicrobial peptide, Antibiotic, Hemolysis

上传时间

2005年01月17日

【期刊论文】Real-time detection of telomerase activity utilizing duplex scorpionprimers and hairpin-like reverse primers

宓怀风, Yan-Ping Huang, ab, De-Ming Kong, a, Qi-Meng Chen, b, Han-Xi Shen*a and Huai-Feng Mi ac

New J.Chem., 2004, 28, 1488-1493,-0001,():

-1年11月30日

摘要

Telomerase, a ribonucleoprotein enzyme, is expected to be a new marker for cancer diagnosis. Thedevelopment of the telomeric repeat amplification protocol (TRAP) and its modified versions have facilitatedthe detection of telomerase activity in small tissue and tumour samples. But most of these techniques requirecomplex post-PCR procedures. As for the two real-time quantitative methods (SYBR Green and Amplifluormethods) reported so far, both use fluorogenic probes without specificity. To overcome these problems wedeveloped a new real-time method for the detection of telomerase activity. In this method a duplex scorpionprimer and reverse primers with hairpin-like structures were used. The use of duplex scorpion primers showsa series of advantages: the target-specific probe sequence provides higher specificity than the SYBR Greenand Amplifluor methods; the unimolecular probing mechanism allow the assay to be conducted under fastcycling conditions and a single operation can be completed in 1.5h; the closed-tube system reduces the riskof carryover contamination and supports high throughput. This method may be a useful tool to rapidly,specifically and precisely quantify telomerase activity.

上传时间

2005年01月17日

【期刊论文】Use of duplex probes simulating TaqMan to detect hepatitis B virus

宓怀风, De-Ming Kong, a, Yan-Ping Huang, Hui Li, Han-Xi Shen*a and Huai-Feng Mi ab

New J. Chem., 2003, 27, 721-726,-0001,():

-1年11月30日

摘要

A novel method for duplex probes is designed to simulate the TaqMan probe during polymerase chain reaction(PCR). In this method, two partly complementary single-labelled oligonucleotide probes labelled with afluorophore or a quencher, respectively, are used. At lower temperature the two probes can bind to each otherand form a mismatched duplex, in which the fluorophore and quencher are in close proximity and the sameenergy transfer mechanism as in molecular beacons may occur between them; thus, a quenching efficiencybetter than conventional TaqMan probes is acquired. In the anneal-extend step of PCR, one single-labelledprobe hybridises to the predetermined target and is cleaved by Taq DNA polymerase. Increased fluorescentsignal can be observed at lower temperature. The fluorescent data analysis demonstrated that a significantlyhigher level of fluorescent signal and hence higher sensitivity of detection is obtainable using our duplex probesin place of conventional TaqMan probes. Combined with real-time PCR instruments, the assay can be used toquantify the input target molecules and the dynamic linear range is of at least six orders of magnitude.

上传时间

2005年01月17日

【期刊论文】Protein Interactions of the MLL PHD Fingers Modulate MLL Target Gene Regulation in Human Cells

宓怀风, KERI FAIR, , MELANIE ANDERSON, ELENA BULANOVA, HUAIFENG MI, MAXIMILIAN TROPSCHUG, AND MANUEL O. DIAZ*

MOLECULAR AND CELLULAR BIOLOGY, May 2001, p. 3589-3597,-0001,():

-1年11月30日

摘要

The PHD fingers of the human MLL and Drosophila trx proteins have strong amino acid sequence conservationbut their function is unknown. We have determined that these fingers mediate homodimerization andbinding of MLL to Cyp33, a nuclear cyclophilin. These two proteins interact in vitro and in vivo in mammaliancells and colocalize at specific nuclear subdomains. Overexpression of the Cyp33 protein in leukemia cellsresults in altered expression of HOX genes that are targets for regulation by MLL. These alterations aresuppressed by cyclosporine and are not observed in cell lines that express a mutant MLL protein without PHDfingers. These results suggest that binding of Cyp33 to MLL modulates its effects on the expression of target genes.

上传时间

2005年01月17日

【期刊论文】Detection of Hepatitis B Virus DNA by Duplex ScorpionPrimer-based PCR Assay†

宓怀风, KONG, De-Ming*, a, b, SHEN, Han-Xi b, MI, Huai-Feng a

Chinese Journal of Chemistry, 2004, 22, 903~907,-0001,():

-1年11月30日

摘要

The application of a new fluorogenic probe-based PCR assay (PCR duplex scorpion primer assay) to the detectionof Hepatitis B virus (HBV) DNA in human sera was described. Duplex scorpion primer is a modified variant ofduplex Amplifluor, and the incorporation of a PCR stopper between probe and primer sequences improve the detectionspecificity and sensitivity. Combined with PCR amplification, this probe can give unambiguous positive resultsfor the reactions initiated with more than 20 HBV molecules. In addition, the particular unimolecular probingmechanism of this probe makes the use of short target-specific probe sequence possible, which will render thisprobe applicable in some specific systems.

duplex scorpion primer,, hepatitis B virus (, HBV), DNA,, fluorogenic probe

合作学者

  • 宓怀风 邀请

    南开大学,天津

    尚未开通主页