您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者1条结果 成果回收站

上传时间

2009年04月12日

【期刊论文】A Dosimetry Model for the Small Intestine Incorporating Intestinal Wall Activity and Cross-Doses

刘小伟, Lena J

,-0001,():

-1年11月30日

摘要

Current internal radiation dosimetry models for the small intestine, and for most walled organs, lack the ability to account for the activity uptake in the intestinal wall. In existing models the cross-dose from nearby loops of the small intestine is not taken into consideration. The aim of this investigation was to develop a general model for calculating the absorbed dose to the radiation-sensitive cells in the small intestinal mucosa from radionuclides located in the small intestinal wall or contents. Methods: A model was developed for calculation of the self-dose and cross-dose from activity in the intestinal wall or contents. The small intestine was modeled as a cylinder with 2 different wall thicknesses and with an infinite length. Calculations were performed for various mucus thicknesses. S values were calculated using the EGS4 Monte Carlo simulation package with the PRESTA algorithm and the simulation results were integrated over the depth of the radiosensitive cells. The cross-organ dose was calculated by summing the dose contributions from other intestinal segments. Calculations of S values for self-dose and cross-dose were made for monoenergetic electrons, 0.050-10 MeV, and for the radionuclides 99mTc, 111In, 131I, 67Ga, 90Y, and 211At. Results: The self-dose S value from activity located in the small intestinal wall is considerably greater than the S values for self-dose from the contents and the cross-dose from wall and contents except for high electron energies. For all radionuclides investigated and for electrons 0.10-0.20 MeV and 8-10 MeV in energy, the cross-dose from activity in the contents is higher than the self-dose from the contents. The mucus thickness affects the S value when the activity is located in the contents. Conclusion: A dosimetric model for the small intestine was developed that takes into consideration the localization of the radiopharmaceutical in the intestinal wall or in the contents. It also calculates the contribution from self-dose and cross-dose. With this model, more accurate calculations of absorbed dose to radiation-sensitive cells in the intestine are possible.

radiation dosimetry, intestine, cross-dose, EGS4, Monte Carlo simulations

合作学者