您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者13条结果 成果回收站

上传时间

2005年04月22日

【期刊论文】Plant Tissue-Based Chemiluminescence Flow Biosensor for Glycolic Acid

李保新, Baoxin Li, Zhujun Zhang, * and Yan Jin

,-0001,():

-1年11月30日

摘要

A novel plant tissue-based chemiluminescence (CL) biosensor for glycolic acid combined with flow injection analysis is proposed in this paper. The spinach tissue acts as the molecular recognition element. Glycolic acid is oxidized by oxygen under the catalysis of glycolate oxidase in the tissue column to produce hydrogen peroxide, which can react with luminol in the presence of peroxidase of spinach tissue to generate a CL signal. The CL emission intensity was linear with glycolic acid concentration in the range of 4

上传时间

2005年04月22日

【期刊论文】Plant tissue-based chemiluminescence flow biosensor for determination of unbound dopamine in rabbit blood with on-line microdialysis sampling

李保新, Baoxin Li, Zhujun Zhang*, Yan Jin

Biosensors and Bioelectronics 17 (2002) 585-589,-0001,():

-1年11月30日

摘要

A novel plant tissue-based chemiluminescence (CL) biosensor for dopamine combined with flow injection analysis is presented in this paper. The potato roots act as molecular recognition elements. Dopamine is oxidized by oxygen under the catalysis of polyphenol oxidase in the tissue column to produce hydrogen peroxide, which can react with luminol in the presence of peroxidase of potato tissue to generate CL signal. The CL emission intensity was linear with dopamine concentration in the range of 1×10-5-1×10-7g/ml and the detection limit was 5.3×10-8g/ml (3σ) with a relative standard deviation of 1.7%. Combined with microdialysis sampling, the biosensor was applied to monitor the variation of dopamine level in the blood of rabbit after the administration of dopamine to demonstrate the favorable resolution and reliability of the system for in vivo on-line monitoring.

Chemiluminescence, Plant tissue-based biosensor, Flow injection, Microdialysis, Dopamine

上传时间

2005年04月22日

上传时间

2005年04月22日

上传时间

2005年04月22日

【期刊论文】Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection

李保新, Baoxin Li, Zhujun Zhang*, Wei Liu

Talanta 54 (2001) 697-702,-0001,():

-1年11月30日

摘要

A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO4-isoniazid was also investigated. The sampling frequency of the system was 120h−1. The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measurin grange and robustness of the system.

Flow-injection analysis, Chemiluminescence, Dissolution testing, Isoniazid

合作学者

  • 李保新 邀请

    陕西师范大学,陕西

    尚未开通主页