您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者10条结果 成果回收站

上传时间

2005年03月04日

【期刊论文】Surface Modification for Controlling the Blood-Materials Interface

黄楠, N.Huang, , a*, P. Yang, Y.X.Leng, J. Wang, J.Y. Chen, H. Sun, G.J. Wan, A.S. Zhao and P.D. Ding

Invited report on 6th Asia Symposium on Biomedical Materials, July 20-23, 2004,-0001,():

-1年11月30日

摘要

In the present paper, the scientific basis, technique approaches, the present status and the development trends of surface modification for blood contacting materials are discussed briefly. The work in authors' Lab. is also presented.

Biomaterials,, Surface Engineering,, Blood compatibility

上传时间

2005年03月04日

【期刊论文】Surface modification of biomaterials by plasma immersion ion implantation

黄楠, N. Huang*, P. Yang, Y.X. Leng, J. Wang, H. Sun, J.Y. Chen, G.J. Wan

Surface & Coatings Technology 186(2004)218-226,-0001,():

-1年11月30日

摘要

The present paper presents the results of surface modifications of biomaterials using plasma immersion ion implantation (PIII) in Institute of Surface Modification of Biomaterials in Southwest Jiaotong University. In the research, titanium oxide films and diamond-like carbon (DLC) films doped with different elements, as well as surface modification of polymers, are prepared using PIII. The blood compatibility of the films is investigated. Significant improvement in blood compatibility of the films compared with those untreated substrate materials is confirmed. The mechanisms of the blood compatibility of the films are discussed. The results show that the energy band structure of the material surface may be a controlling factor in the blood compatibility of the material. A film with an n-type semiconductor nature would have a better blood compatibility. Improvement in wear resistance of hip joint and modification of antibacterial property of artificial heart valve suture ring material is also presented in the paper.

Surface modification, Biomaterials, Biocompatibility, Plasma immersion ion implantation

上传时间

2005年03月04日

【期刊论文】Inhibition of adherent platelet activation produced by Ti-O thin film fabricated by PIII

黄楠, P. Yang, N. Huang*, Y.X. Leng, J.Y. Chen, H. Sun, J. Wang, G.J. Wan

Surface & Coatings Technology 186(2004)265-269,-0001,():

-1年11月30日

摘要

Thrombogenesis is the principal problem associated with blood-contacting biomedical devices. One of the important reasons is that most of the materials used in these devices cannot avoid inducing platelet adhesion and activation. Our recent investigation suggested that Ti-O thin film could be an alternative antithrombotic material. In this work, we focus our attention on behavior of platelets adhered on Ti-O film. Platelet adhesion experiments were conducted to examine the platelets/material interaction in vitro and the effect of protein adsorption on platelet adhesion and activation. The specific resultants of platelet release (GMP140) were tested for evaluating the platelet activation. In vivo implantation was used to investigate formation of thrombus. The excellent anticoagulation performance of Ti-O films has been shown in in vivo long-term mplantation. The release of specific resultants GMP140 from platelets contacting to Ti-O film was the lower than LTI-carbon. The morphology of adherent platelets maintainsround and isolated. Apparently, the activation of platelets adhered on Ti-O film was suppressed. The results of in vitro test also suggest that the suppression of platelet activation is related to plasma protein adsorption. Preadsorbing fibrinogen doesn't cause the exacerbation of platelet activation. It seems reasonable to suggest that its excellent anticoagulation is caused by inhibition of adherent platelet activation produced by Ti-O film.

Blood compatibility, Platelet activation, Protein adsorption, Ti-O film

上传时间

2005年03月04日

【期刊论文】Synthesis of nitrogen incorporated carbon films by plasma immersion ion implantation and deposition

黄楠, F. Wen, N. Huang*, H. Sun, J. Wang, Y.X. Leng

Surface & Coatings Technology 186(2004)118-124,-0001,():

-1年11月30日

摘要

Nitrogen incorporated carbon films were synthesized using plasma immersion ion implantation and deposition at room temperature. Nitrogen partial pressure was varied from 1.0

Carbon nitride films, X-ray photoelectron spectrum, Raman spectrum, Optical band gap

上传时间

2005年03月04日

【期刊论文】STATE-OF-THE-ART OF SURFACE MODIFICATION OF BIOMATERIALS APPLIED FOR CARDIOVASCULAR DEVICES

黄楠, N. Huang, P. Yang, Y.X.Leng, L.J. Chen, H. Sun, J.Wang and G.J. Wan

Key note speaker on 3rd International conference on surface engineering, Sept. 10-13, 2002, Chengdu, China, pp 453-456,-0001,():

-1年11月30日

摘要

Surface modification has become a important field in biomaterials research because of the low cost, the high efficacy and the versatility. In this paper some recent applications of surface modification technology on the materials for cardiovascular devices were provided. Three ategories of the surface modification process, biological molecular immobilization, chemical medium binding and energy carrier substances coating or modification are discussed, the authors series work on the surface modification of artificial heart valve and vascular stents etc. are presented. The further development of the field is also discussed.

Surface modification,, Biomaterials,, cardiovascular devices Blood compatibility

合作学者

  • 黄楠 邀请

    西南交通大学,四川

    尚未开通主页