您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者11条结果 成果回收站

上传时间

2005年03月25日

【期刊论文】Scanning Electrochemical Microscopy in Combination with Piezoelectric Quartz Crystal Impedance Analysis for Studying the Growth and Electrochemistry as Well as Microetching of Poly(o-phenylenediamine) Thin Films

谢青季, Xinman Tu, † Qingji Xie, *, †, ‡ Canhui Xiang, ‡ Youyu Zhang, † and Shouzhuo Yao†

,-0001,():

-1年11月30日

摘要

The combination of scanning electrochemical microscopy (SECM) with piezoelectric quartz crystal impedance (PQCI) analysis was proposed as a novel multiparameter method for investigating the cyclic voltammetric growth of poly(o-phenylenediamine) (PoPD) thin films at Au electrodes in aqueous solutions of various pH values and the potentiostatic microetching (localized degradation) of these films in 0.10mol/L aqueous H2-SO4 for comparative examinations on polymer porosity and stability. Two potential-sweep ranges, -0.4 to 0.9 (I) and 0 to 0.9 (II) V versus SCE, and four solutions, acidic (A, 0.20mol/L H2SO4 + 0.10mol/L Na2-SO4; B, 0.10mol/L H2SO4 + 0.20mol/L Na2SO4), neutral (C, 0.10 mol/L PBS + 0.20mol/L Na2SO4, pH 7.2), and alkaline (D, 0.20mol/L NaOH + 0.20mol/L Na2SO4) aqueous solutions, were selected for PoPD growth. The pH increase for the polymerization solution increased the molar percentage of polyaniline-like chains in PoPD, as quantified from the current peaks at 0.6 V versus a saturated calomel electrode (SCE) for the oxidation of -NH2 groups in as-prepared PoPD (grown from solutions C and D) during their redox switching in 0.10mol/L aqueous H2SO4 for the first time. The unusual PQCI responses observed at negative potentials (potential range I) in the first several potential cycles during the cyclic voltammetric growth of PoPD in acidic and neutral solutions have been reasonably explained as being due to the precipitation/dissolution of the poorly soluble phenazinehydrine charge-transfer complexes developed during redox switching of oligomers for the first time, which brought about much less compact PoPD films and their higher degradability than those grown in the same solution but over potential range II. SECM, scanning electron microscopy (SEM), and piezoelectric quartz crystal (PQC) frequency were used to estimate the sizes of etched microscale spots. In addition, the x-, y-, or z-axis movement of a Pt microelectrode of 25-

合作学者

  • 谢青季 邀请

    湖南师范大学,湖南

    尚未开通主页