您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者19条结果 成果回收站

上传时间

2006年01月17日

【期刊论文】Creeping Discharge Performance of Oil-paper Insulation with Streaming Electrification

丁立健, Yang Jia-Xiang, Chi Xiao-Chun, Ding Li-Jian and Liu Ji

IEEE Transactions on Dielectrics and Electrical Insulation Vol.4 No.6, December I997 780~784,-0001,():

-1年11月30日

摘要

In this paper, the influence of streaming electrification on the creeping discharge of oil-paper insulation system has been investigated, using experimental models. The experimental results indicate that the initial creeping discharge voltage of oil-paper insulation system decreases with oil flow rate. The creeping discharge path develops toward the oil entrance, and there are polarity and position effects on creeping discharge under oil flowing conditions. Reasons of failure due to dendritic discharge on the surface of barrier boards in power transformers have been revealed in these experiments.

上传时间

2006年01月17日

【期刊论文】Influences of Electrical Field on Boiling-Condensation Heat Transfer System

丁立健, Yang Jia-Xiang, Ding Li-Jian, Chi Xiao-Chun, Liu Ji, Yang He

Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, Montreal, Qubec, Canada, June 16-19, 1996,-0001,():

-1年11月30日

摘要

In this paper, the Influences of electrical field on boiling-condensation heft transfer system have been investigated using a cylinder beat transfer model Freon-ll is selected as working fluid. The condensation heat transfer coefficient, the boiling heat flux the saturation pressure are meassured in this investigation. According to the experimental results, it is found that the electrical field can influence best transfer system. The boiling heat transfer is enhanced by the applied voltage, and the saturate vapor of working fluid is condensed on the high voltage electrode directly when the applied voltage is higher than 6kv. The experimental results have been discussed, and it is considered that the high electrical field strength change the thermal properties of working fluid.

上传时间

2006年01月17日

【期刊论文】A Preliminary Study of Oil-Polypropylene Insulating System

丁立健, Chi Xiao-Chun Ding Li-Jian, Yang Jia-Xiang

Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, Montreal, Qubec, Canada, June 16-19, 1996,-0001,():

-1年11月30日

摘要

In this paper, creeping discharge of oil-polypropylene insulating system have been studied using an experimental model with the flowing oil under ac voltage. The ac creeping discharge inception voltage of the oil-polypropylene system has been tested under varied conditions. According to the experimental results, all of the oil temperature, the oil flow rate and the position of poly propylene film can influence the ac creeping discharge inception voltage of oil-polypropylene system. The ac inception voltage of this system is increased along with the increase of oil temperature and oil flow rate. Moreover, the ac inception voltage is higher at the position near to oil entrance than that at the position far to oil entrance. Considering the experimental results, a new composite insulating system is put forward for reducing the negative effects of streaming electrification in larger power devices with forced-oil cooling systems.

上传时间

2006年01月17日

【期刊论文】Generator PD Measurement by Using UHF and HF Sensors

丁立健, Xin Li*, C.R. Li, Lijian Ding, Wei Wang, Weijiang Wan

Conference Record of the 2004 IEEE International Symposium on Electrical Insulation, Indianapolis, IN USA, 19-22 September 2004,-0001,():

-1年11月30日

摘要

A measuring system for on-line detecting partial discharge of generators has been designed with the ultra high frequency (UHF) and high frequency (HF) method. It not only has the capability of calibrating the PD level, but also has the excellent ability of anti-interfering on site. The test data shows this technique is very promising.

上传时间

2006年01月17日

【期刊论文】Experimental Investigation of Influence of Surface Roughness on Flashover Performance of Ceramics In Vacuum

丁立健, Lijian Ding, Youping Tu, C.R. Li, Wei Wang

Conference Record of the 2004 IEEE International Symposium on Electrical Insulation, Indianapolis, IN USA, 19-22 September 2004,-0001,():

-1年11月30日

摘要

This paper provides some experimental investigation on the influence of the surface roughness on the flashover performance of ceramics in vacuum. The test samples were prepared with four kinds of ceramics (99.9% Alumina) which were polished by four different SIC abrasives. The flashover performances of 20 kinds of test samples have been tested with an impulse voltage in vacuum. According to the experimental results, it was found that the roughness of the test sample was quite different among different ceramics although the same grinding procedure was used with the same abrasive. It was also found that the flashover performance was influenced by the surface roughness, and there is a trend that the samples with a lower surface roughness have a higher breakdown voltage.

合作学者

  • 丁立健 邀请

    华北电力大学,河北

    尚未开通主页