104浏览
-
0点赞
-
0收藏
-
0分享
-
92下载
-
0评论
-
引用
期刊论文
A thermoacoustically driven pulse tube refrigerator capable of working below 120 K
Cryogenics 41(2001)595-601,-0001,():
Based on the discussion of the matching problems between the prime mover and pulse tube, a self-made standing-wave ther-moacoustic prime mover is used to drive a coaxial single-stage pulse tube refrigerator A lowest refrigeration temperature of 138 K was obtained from the preliminary tests in 1999 Then, some improvements have been made to the heat exchangers and the con-nection between prime mover and pulse tube The minimum cooling temperatures of ll9.7 and ll7.6 K have been obtained from therecent experiments with helium andhelium-argon mixture filling of 2.0 MPa as the working fluids, respectively Itis a great progress for the standing-wave machine and provides the possibility of liquefying natural gas of 0.2 MP.
【免责声明】以下全部内容由[陈国邦]上传于[2006年08月07日 17时39分26秒],版权归原创者所有。本文仅代表作者本人观点,与本网站无关。本网站对文中陈述、观点判断保持中立,不对所包含内容的准确性、可靠性或完整性提供任何明示或暗示的保证。请读者仅作参考,并请自行承担全部责任。
本学者其他成果
同领域成果