您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者7条结果 成果回收站

上传时间

2009年07月07日

【期刊论文】Derivative Flame Atomic Absorption Spectrometry and Its Application in Trace Analysis

孙汉文, H.W. Sun* and L.Q. Li

Journal of the Iranian Chemical Society, Vol. 2, No.4, December (2005), pp. 268-276.,-0001,():

-1年11月30日

摘要

Flame atomic absorption spectrometry (FAAS) is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for FAAS. The signal models of conventional FAAS are described. The equations of derivative signals are established for FAAS, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dI/dt) is different from the derivative spectrophotometry (DS) based on determination of variation rate of signal intensity with wavelength (dI/dλ). Derivative flame atomic absorption spectrometry (DFAAS) has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of DFAAS are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples.

Signal models, Derivative technique, Atomic absorption spectrometry, Analytical performance, Trace analysis

上传时间

2009年07月07日

【期刊论文】Enhancement reagents for simultaneous vapor generation of zinc and cadmium with intermittent flow system coupled to atomic fluorescence spectrometry

孙汉文, Han-Wen Suna, Ran Suoa, b, ∗

Analytica Chimica Acta 509(2004)71-76,-0001,():

-1年11月30日

摘要

Simultaneous vapor generation of zinc (Zn) and cadmium (Cd) was evaluated by atomic fluorescence spectrometry coupled with an intermittent flow vapor generation system. Some complexing reagents, surfactant and transition metal ions were respectively tested as enhancement reagents. Experiments showed that an appropriate amount of 8-hydroxyquinoline or phenanthroline and nickel ion simultaneously, effectively improved the vapor generation efficiency of Zn and Cd. The volatile species generation was presumed to be a hydrogenation process interpreting how the enhancement reagents played an important role in vapor generation. Additionally, due to the instability of volatile species, reaction temperature, rapid and sufficient mixing of reagents and rapid separation of the volatile species from liquid phase were also crucial. The method of simultaneous determination of Zn and Cd by intermittent flow vapor generation led to the development of atomic fluorescence spectrometry. The detection limits (3σb) were 1.6μg l−1 for Zn and 0.01μg l−1 for Cd and the relative standard deviations were 3.6% for Zn (50μg l−1, n=11) and 1.7% for Cd (2μg l−1, n=11) respectively. Results for the determination of Zn and Cd have been confirmed by the analysis of CRMs with good agreement between the certified and found values.

Enhancement reagent, Vapor generation, Atomic fluorescence spectrometry, Zinc and cadmium

合作学者

  • 孙汉文 邀请

    河北大学,河北

    尚未开通主页