您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者7条结果 成果回收站

上传时间

2009年05月08日

【期刊论文】Direct competitive immunoassays for the coplanar polychlorinated biphenyls

邓安平, Milan Fránek a, ∗, Anping Denga, Vladimir Kolar a, Jaromir Socha b

Analytica Chimica Acta 444(2001)131-142,-0001,():

-1年11月30日

摘要

lic acid spacers at para-position were derived from coplanar 3,3,4,4-tetrachlorobiphenyl and 3,3_,4,4_,5-pentachlorobiphenyl (IUPAC No. 77 (PCB 77) and 126 (PCB 126), respectively). It appeared from the results that the length of the spacer did not affect significantly the sensitivity of the assays established. The direct ELISAs using the antibodies in combination with various hapten–peroxidase tracers showed IC50-values for polychlorinated biphenyl (PCB) 77 and 126 of 1.3–19.2μg l−1. The ELISAs were tested for their cross-reactivity profiles using 20 selected congeners. The assays were highly specific for non-ortho-substituted (coplanar) congeners and did not recognize the more abundant but less toxic non-coplanar PCBcongeners or organochlorine compounds. The superior assaywas found for the antibody againstPCB126-(CH2)3-hapten mimic–bovine serum albumin (BSA) in combination with PCB 77-CH2-hapten mimic-peroxidase tracer. The IC50-values for the assay to PCB 77 and 126 were 2.0 and 5.2μg l−1, respectively; the highest cross-reactivity values (PCB 126=100%) achieved for non-coplanar structures and metabolites were only 1.3 and 1.0% for 2,3,3,4,4,5,5 heptachlorobiphenyl (PCB 189) and PCB 77 ether, respectively. In order to interpret measured data in terms of analytical or toxicological equivalents, a reliable relationship between assay responses and the coplanar congener content of Aroclor-contaminated samples should be verified and validated.

Immunoassays, Immunogen, Tracer, Spacer, Coplanar PCBs, Cross-reactivity, Dose-response

上传时间

2009年05月08日

【期刊论文】Performance characteristics for flow injection immunoassay using monoclonal antibodies against s-triazine and 2,4-D herbicides

邓安平, Milan Frane*, Anping Deng, Vladimir Kolar

Analytica Chimica Acta 412(2000)19-27,-0001,():

-1年11月30日

摘要

A sequential injection instrument (ALITEA, USA) with a photometric and fluorometric detection unit S2000 (Ocean Optics) was employed for the development of flow injection immunoanalysis (FIIA). The monoclonal antibodies against atrazine, simazine and 2,4-D were immobilized on aminopropyl glass particles by means of avidin/biotin system and packed in plexiglass column of 18ml volume. Assay characteristics for individual antibody-reactors and regeneration effectivities for acid and alkaline solutions are described. An attempt to prepare a functional mixed antibody-reactor has not achieved success since regeneration conditions found for individual reactors were not compatible with one performance protocol.

Flow injection immunoassay, Monoclonal antibodies, Immunoreactor, Regeneration, Calibration

合作学者

  • 邓安平 邀请

    四川大学,973,863首席科学家

    尚未开通主页