已为您找到该学者7条结果 成果回收站
【期刊论文】Direct competitive immunoassays for the coplanar polychlorinated biphenyls
邓安平, Milan Fránek a, ∗, Anping Denga, Vladimir Kolar a, Jaromir Socha b
Analytica Chimica Acta 444(2001)131-142,-0001,():
-1年11月30日
lic acid spacers at para-position were derived from coplanar 3,3,4,4-tetrachlorobiphenyl and 3,3_,4,4_,5-pentachlorobiphenyl (IUPAC No. 77 (PCB 77) and 126 (PCB 126), respectively). It appeared from the results that the length of the spacer did not affect significantly the sensitivity of the assays established. The direct ELISAs using the antibodies in combination with various hapten–peroxidase tracers showed IC50-values for polychlorinated biphenyl (PCB) 77 and 126 of 1.3–19.2μg l−1. The ELISAs were tested for their cross-reactivity profiles using 20 selected congeners. The assays were highly specific for non-ortho-substituted (coplanar) congeners and did not recognize the more abundant but less toxic non-coplanar PCBcongeners or organochlorine compounds. The superior assaywas found for the antibody againstPCB126-(CH2)3-hapten mimic–bovine serum albumin (BSA) in combination with PCB 77-CH2-hapten mimic-peroxidase tracer. The IC50-values for the assay to PCB 77 and 126 were 2.0 and 5.2μg l−1, respectively; the highest cross-reactivity values (PCB 126=100%) achieved for non-coplanar structures and metabolites were only 1.3 and 1.0% for 2,3,3,4,4,5,5 heptachlorobiphenyl (PCB 189) and PCB 77 ether, respectively. In order to interpret measured data in terms of analytical or toxicological equivalents, a reliable relationship between assay responses and the coplanar congener content of Aroclor-contaminated samples should be verified and validated.
Immunoassays, Immunogen, Tracer, Spacer, Coplanar PCBs, Cross-reactivity, Dose-response
-
35浏览
-
0点赞
-
0收藏
-
0分享
-
55下载
-
0
-
引用
邓安平, Milan Frane*, Anping Deng, Vladimir Kolar
Analytica Chimica Acta 412(2000)19-27,-0001,():
-1年11月30日
A sequential injection instrument (ALITEA, USA) with a photometric and fluorometric detection unit S2000 (Ocean Optics) was employed for the development of flow injection immunoanalysis (FIIA). The monoclonal antibodies against atrazine, simazine and 2,4-D were immobilized on aminopropyl glass particles by means of avidin/biotin system and packed in plexiglass column of 18ml volume. Assay characteristics for individual antibody-reactors and regeneration effectivities for acid and alkaline solutions are described. An attempt to prepare a functional mixed antibody-reactor has not achieved success since regeneration conditions found for individual reactors were not compatible with one performance protocol.
Flow injection immunoassay, Monoclonal antibodies, Immunoreactor, Regeneration, Calibration
-
28浏览
-
0点赞
-
0收藏
-
0分享
-
37下载
-
0
-
引用