已为您找到该学者10条结果 成果回收站
鞠熀先, Jiuhong Yu, Songqin Liu, Huangxian Ju *
Biosensors and Bioelectronics 19(2003)509-514,-0001,():
-1年11月30日
A novel amperometric phenol sensor was constructed by immobilizing tyrosinase in a titania sol-gel matrix. The tyrosinase entrapped sol-gel film was obtained with a vapor deposition method, which simplified the traditional sol-gel process and avoided the shrinkage and cracking of conventional sol-gel-derived glasses. This matrix provided a microenvironment for retaining the native structure and activity of the entrapped enzyme and a very low mass transport barrier to the enzyme substrates. Phenol could be oxidized by dissolving oxygen in presence of immobilized tyrosinase to form a detectable product, which was determined at-150 mV without any mediator. The phenol sensor exhibited a fast response (less than 5 s) and sensitivity as high as 103μA/mM, which resulted from the porous structure and high enzyme loading of the sol-gel matrix. The linear range for phenol determination was from 1.2×10-7 to 2.6×10-4 M with a detection limit of 1.0×10-7M. The apparent Michaelis-Menten constant of the encapsulated tyrosinase was calculated to be (0.299±0.02) mM. The stability of the biosensor was also evaluated.
Sol-gel, Tyrosinase, Titania, Biosensors, Vapor deposition
-
30浏览
-
0点赞
-
0收藏
-
0分享
-
182下载
-
0
-
引用
鞠熀先, Jianhua Zhao a*, Feng Yan a, Huangxian Ju b, *, Jinhai Tang c, Jianwei Qin c
Cancer Letters 204(2004)87-95,-0001,():
-1年11月30日
Serum vascular endothelial growth factor (VEGF) and endostatin levels were detected in 59 patients with breast cancer before surgery and at 3 weeks after surgery. Pre-operatively, their levels were significantly elevated and correlated with each other. Post-operatively, VEGF level decreased significantly and endostatin remained at a high level. Patients with both normalized VEGF and elevated endostatin following surgery had a lower risk of relapse than patients whose VEGF failed to normalize. Univariate and multivariate analyses showed a correlation between elevated VEGF level and short free-relapse survival. These findings suggest a new angiogenesis balance is formed in the patients after surgery and such a resultant balance may be beneficial for the prognosis of breast cancer, which deserves more extensive study.
Angiogenesis, Endostatin, Primary breast cancer, Vascular endothelial growth factor
-
42浏览
-
0点赞
-
0收藏
-
0分享
-
182下载
-
0
-
引用
鞠熀先, Y.K. Ye a, J.H. Zhao b, F. Yan b, Y.L. Zhu a, H.X. Ju a, *
Biosensors and Bioelectronics 18(2003)1501-1508,-0001,():
-1年11月30日
Sequence-known short-stranded hepatitis B virus (HBV) DNA fragment (181 bps) was obtained by PCR method. The strategy for its electrochemical detection was designed by covalently immobilizing single-stranded HBV DNA on gold electrode surface via carboxylate ester as a linkage between 3'-hydroxy end of DNA and carboxyl group of thioglycolic acid (TGA) self-assembled monolayer. The hybridization reaction on surface was evidenced by electrochemical methods using ferrocenium hexafluorophosphate (FcPF6) as an electroactive indicator. The interactions of Fc+with single-stranded (ss) and double-stranded (ds) HBV DNA immobilized on TGA monolayer were studied. The difference between the responses of Fc+at ss-and ds-DNA/Au electrodes suggested that this hybridization biosensor could be conveniently used to monitor DNA hybridization with a high sensitivity. AC impedance and XPS techniques have been employed to characterize the immobilization of ss-DNA on the gold surface.
Hepatitis B virus, PCR, Self-assembled monolayer, Biosensors, Ferrocenium hexafluorophosphate
-
63浏览
-
0点赞
-
0收藏
-
0分享
-
168下载
-
0
-
引用
鞠熀先, Songqin Liu and Huangxian Ju*
Analyst, 2003, 128, 3-7,-0001,():
-1年11月30日
0.1 to 9.7 μmol dm-3 and a detection limit of 0.06 μmol dm-3 at 3σ. The amperometric determination of high concentrations of NO2-based on the irreversible reduction of NO could be performed at pH 4.0 with a linear range from 0.1 to 1.2 mmol dm-3. The surface of biosensor could be renewed quickly and reproducibly by a simple polish step. The biosensor has been used satisfactorily for nitrite determination in native water samples.
-
44浏览
-
0点赞
-
0收藏
-
0分享
-
130下载
-
0
-
引用
鞠熀先, Huang-Xian Ju, a, *, Yong-Kang Ye, Jian-Hua Zhao, b and Yong-Lin Zhu a
Analytical Biochemistry 313(2003)255-261,-0001,():
-1年11月30日
A novel hepatitis B virus (HBV) DNA biosensor was developed by immobilizing covalently single-stranded HBV DNA fragments to a gold electrode surface via carboxylate ester to link the 3'-hydroxy end of the DNA with the carboxyl of the thioglycolic acid (TGA) monolayer. A short-stranded HBV DNA fragment (181 bp) of known sequence was obtained and amplified by PCR. The surface hybridization of the immobilized single-stranded HBV DNA fragment with its complementary DNA fragment was evidenced by electrochemical methods using [Os(bpy)2Cl2]+as a novel electroactive indicator. The formation of double-stranded HBV DNA on the gold electrode resulted in a great increase in the peak currents of [Os(bpy)2Cl2]+in comparison with those obtained at a bare or single-stranded HBV DNA-modified electrode. The mismatching experiment indicated that the surface hybridization was specific. The difference between the responses of [Os(bpy)2Cl2]+at single-stranded and double-stranded DNA/TGA gold electrodes suggested that the label-free hybridization biosensor could be conveniently used to monitor DNA hybridization with a high sensitivity. X-ray photoelectron spectrometry technique has been employed to characterize the immobilization of singlestranded HBV DNA on a gold surface.
Electrochemical DNA biosensor, Polymerase chain reaction, Hepatitis B virus, Hybridization, [Os(, bpy), 2Cl2]
-
29浏览
-
0点赞
-
0收藏
-
0分享
-
54下载
-
0
-
引用