您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者20条结果 成果回收站

上传时间

2015年01月24日

【期刊论文】PD Characteristics and Microscopic Analysis of Polyimide Film Used as Turn Insulation in Inverter-fed Motor

吴广宁, Yang Luo, Guangning Wu, Jiwu Liu, Guangya Zhu, Peng Wang, Jia Peng, Kaijang Cao

,-0001,():

-1年11月30日

摘要

上传时间

2015年01月24日

【期刊论文】Study on Charge Transport Mechanism and Space Charge Characteristics of Polyimide Films

吴广宁, L. R. Zhou, G. N. Wu, B. Gao, K. Zhou, J. Liu, K. J. Cao andL. J. Zhou

,-0001,():

-1年11月30日

摘要

Inverter-fed motor,, polyimide,, charge transport,, space charge,, PEA,, pulse voltage,, aging

上传时间

2015年01月24日

【期刊论文】Modeling of Transient Moisture Equilibrium in Oil-paper Insulation

吴广宁, L.J. Zhou, G.N. Wu and J. Liu

,-0001,():

-1年11月30日

摘要

Moisture equilibrium,, oil insulation,, paper insulation,, transient model.,

上传时间

2015年01月24日

【期刊论文】Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge

吴广宁, WU GuangNing , BIAN ShanShan , ZHOU LiRen , ZHANG XueQin , RAN HanZheng, YU ChengLong

,-0001,():

-1年11月30日

摘要

high voltage,, storage capacitor,, partial discharge,, composite insulation,, DC,, pattern recognition

上传时间

2015年01月24日

【期刊论文】Microscopic degradation mechanism of polyimide film caused by surface discharge under bipolar continuous

吴广宁, Luo Yang, Wu Guang-Ning, Liu Ji-Wu, Peng Jia, Gao Guo-Qiang, Zhu Guang-Ya, Wang Peng, Cao Kai-Jiang

,-0001,():

-1年11月30日

摘要

Polyimide (PI) film is an important type of insulating material used in inverter-fed motors. Partial discharge (PD) under a sequence of high-frequency square impulses is one of the key factors that lead to premature failures in insulation systems of inverter-fed motors. In order to explore the damage mechanism of PI film caused by discharge, an aging system of surface discharge under bipolar continuous square impulse voltage (BCSIV) is designed based on the ASTM 2275 01 standard and the electrical aging tests of PI film samples are performed above the partial discharge inception voltage(PDIV). The chemical bonds of PI polymer chains are analyzed through Fourier transform infrared spectroscopy (FTIR)and the dielectric properties of unaged and aged PI samples are investigated by LCR testers HIOKI 3532-50. Finally, the micro-morphology and micro-structure changes of PI film samples are observed through scanning electron microscopy (SEM). The results show that the physical and chemical effects of discharge cut off the chemical bonds of PI polymerchains. The fractures of ether bond (C–O–C) and imide ring (C–N–C) on the backbone of a PI polymer chain leads to the decrease of molecular weight, which results in the degradation of PI polymers and the generation of new chemical groups and materials, like carboxylic acid, ketone, aldehydes, etc. The variation of microscopic structure of PI polymers can change the orientation ability of polarizable units when the samples are under an AC electric field, which would cause the dielectric constant e to increase and dielectric loss tan d to decrease. The SEM images show that the degradation path of PI film is initiated from the surface and then gradually extends to the interior with continuous aging. The injection charge could result in the PI macromolecular chain degradation and increase the trap density in the PI polymer bulk.

合作学者

  • 吴广宁 邀请

    西南交通大学,四川

    尚未开通主页