您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者13条结果 成果回收站

上传时间

2005年04月22日

上传时间

2005年04月22日

上传时间

2005年04月22日

【期刊论文】Flow-injection chemiluminescence detection for studying protein binding for drug with ultrafiltration sampling

李保新, Baoxin Li, Zhujun Zhang*, Lixia Zhao

Analytica Chimica Acta 468 (2002) 65-70,-0001,():

-1年11月30日

摘要

The novel flow chemiluminescence (CL) system for determination of pipemidic acid was proposed, which was based on the sensitizing effect of pipemidic acid on the CL oxidation of sulfite by KMnO4 in acid media. Combined with the technique of ultrafiltration, the flow-injection CL system was applied to study in vitro the bovine serum album (BSA) binding of pipemidic acid. The estimated association constant (K) and the number of the binding site (n) on one molecule of BSA were 8.81

Chemiluminescence, Drug-protein interaction, Ultrafiltration sampling, Flow injection

上传时间

2005年04月22日

【期刊论文】Chemiluminescence flow-through sensor for pipemidic acidusing solidsod ium bismuthate as an oxidant

李保新, Baoxin Li, Zhujun Zhang*, Lixia Zhao, Chunli Xu

Analytica Chimica Acta 459 (2002) 19-24,-0001,():

-1年11月30日

摘要

A novel chemiluminscence (CL) flow-through sensor for pipemidic acid is described. It was based on the sensitizing effect of pipemidic acid on the CL oxidation of sulfite by sodium bismuthate in H2SO4 media. The solid-phase sodium bismuthate was mechanicially immobilized on the sponge rubber inside of the CL flow cell as CL oxidant. The calibration graph is linear in the range 0.1-10g/ml with a detection limit of 6.2×10−8g/ml (3σ). A complete analysis couldbe performedin 1 min with a relative standard deviation (R.S.D.) of 2.5% for 2g/ml pipemidic acid (n=8). This methodhas been successfully applied to determine pipemidic acid in pharmaceutical preparation.

Chemiluminscence, Flow-through sensor, Pipemidic acid, Sodium bismuthate, Solid-phase oxidant

上传时间

2005年04月22日

【期刊论文】Chemiluminescence flow biosensor for determination of total D-amino acid in serum with immobilized reagents

李保新, Baoxin Li, Zhujun Zhang*

Sensors and Actuators B 69 2000. 70-74,-0001,():

-1年11月30日

摘要

A flow-injection chemiluminescence CL.biosensor for the determination of total D-amino acid is described in this paper. D-amino acid oxidase was immobilized onto amine-modified silica gel via glutaraldehyde activation and packed in a column. The other analytical reagents, including luminol and ferricyanide, were electrostatically co-immobilized on an anion-exchange column. D-amino acid was sensed by the CL reaction between hydrogen peroxide produced from the enzyme column and luminol and ferricyanide, which were eluted from the ion-exchange column through sodium phosphate injection. The linear range of D-alanine concentration is 1.1×10-6 to 1.1×10-4mol/l and the detection limit was 4.5×10-7mol/l (3σ). The proposed method has been successfully applied to the determination of D-amino acid in human serum.

Chemiluminescence, Flow biosensor, D-amino acid, Immobilized reagent

合作学者

  • 李保新 邀请

    陕西师范大学,陕西

    尚未开通主页