您当前所在位置: 首页 > 学者
在线提示

恭喜!关注成功

在线提示

确认取消关注该学者?

邀请同行关闭

只需输入对方姓名和电子邮箱,就可以邀请你的同行加入中国科技论文在线。

真实姓名:

电子邮件:

尊敬的

我诚挚的邀请你加入中国科技论文在线,点击

链接,进入网站进行注册。

添加个性化留言

已为您找到该学者20条结果 成果回收站

上传时间

2005年11月30日

【期刊论文】Methods to improve the bus throughput of node computer in optical interconnection network

周革, Feng Tang*, Wencai Jing, Yimo Zhang, Ge Zhou, Dagong Jia, fanmin Kong, Zhixiang Sun

,-0001,():

-1年11月30日

摘要

Both hardware and software are optimized simultaneously to improve the bus throughput of node computer in cluster computing network. A cost effective optical interconnection ring network is established using off-the-shelf PCs with windows operating system. A network adapter card ONIC is developed. Using ETDM and field program technique, the 1511 bandwidth of the 32bit

Optical interconnection, user-level interface, throughput, latency, computing cluster, end-system.,

上传时间

2005年11月29日

【期刊论文】Measurement accuracy improvement with PZT scanning for detection of DPC in Hi-Bi fibers

周革, Wencai Jing, Yimo Zhang, Ge Zhou, Feng Tang, and Haifeng Li

OPTICS EXPRESS 690, 2002, 10 (15),-0001,():

-1年11月30日

摘要

Piezo-electronic transducer is used in combination with mechanical scanning devices to improve measurement accuracy in a distributed polarization coupling detection system. For mechanical scanning range of 150mm with 200nm resolution, the measurement error of polarization-coupling intensity can be improved from 38% to 2% in combination with a 20-nm resolution piezo-electronic transducer.

上传时间

2005年11月30日

【期刊论文】Rotation angle optimization of the polarization eigenmodes for detection of weak mode coupling in birefringent waveguides

周革, Wencai Jing, Yimo Zhang, Ge Zhou, Hongxia Zhang, Zhaohui Li, and XiaomingMan

OPTICS EXPRESS, 2002, 10 (18),-0001,():

-1年11月30日

摘要

White light interferometry has been adopted to measure distributed polarization coupling in high-birefringence waveguides. Since the coupling mode is weak compared to the exciting mode, the contrastratio of the interferogram is very low. This will increase the difficulty of direct detection of the polarization coupling intensity. By rotating the angle between the polarization eigenmodes and the principal axis of the linear polarizer from 45˚ to 85˚, the contrast ratio of the interferogram can be improved more than 10 times. As a result, the measurement sensitivity can be improved more than 100 times.

上传时间

2005年11月30日

【期刊论文】Detection of distributed polarization coupling in high birefringenee fibers

周革, Wencai Jing*, Yimo Zhang, Ge Zhou, Haifeng Li Zhaohui Li, Hongxia Zhang, Xiaoming Man, Feng Tang

Proc. SPIE Vol. 4927,-0001,():

-1年11月30日

摘要

White light interferometry has been adopted to measure the distributed polarization coupling in high bireffingence thers A supoduminescent diode is adopted as the optical source in the white light interierometer To enlarge the reasorement range, the light beam in the scanning arm of the Micbelson interferometer is reflected three limes. Thus descanning range of the interferometer is doubled The full-width half-maximum spectrum of the SLD is 50nm, and cesenal wavelength is 1300mm. If the modal birefdngence of the I-IBF is 5

white light interferometry, high birefdngence fiber, distributed polaization coupling, coupling intensity, spatical resolution

上传时间

2005年11月30日

【期刊论文】Analysis of the influence of opto-electro-mechanical devices on the measurement accuracy of a distributed polarization detection system

周革, Wencai Jing , Yimo Zhang, Ge Zhou and Feng Tang

Meas. Sci. Technol. 14(2003)294-300,-0001,():

-1年11月30日

摘要

In this paper, white light interferometry has been used to measure the distributed polarization coupling in high birefringence fibres. Detailed theoretical analysis of the measurement accuracy of the testing system is presented. The main part is a Michelson interferometer with a scanning arm driven by a stepping motor. The minimum polarization coupling intensity detectable by this system is -77dB. The maximum fibre length that can be tested under this design is more than 1km, and the spatial resolution is better than 50mm. The influence of the opto-electro-mechanical devices on measurement accuracy has been analysed in order to improve the performance-to-cost ratio. This testing system can also be used in coherence division multiplexing optical fibre sensors.

white light interferometry, Michelson interferometer, polarization coupling intensity, spatial resolution, coherence division multiplexing

合作学者

  • 周革 邀请

    天津大学,天津

    尚未开通主页