【期刊论文】Model for prediction of oxygen required in BOF steelmaking
刘青, Z.Wang, , Q.Liu*, F.M.Xie, B.Wang, X.C.Lu, and G.Q.Fu
Ironmaking and Steelmaking,-0001,():
-1年11月30日
By analysing the factors that affect oxygen consumption during the basic oxygen furnace steelmaking process, a multiple linear regression model for predicting the oxygen blowing quantity was obtained on the basis of actual production data. Additionally, an oxygen balance model for prediction of the oxygen blowing quantity was established on the basis of oxygen balance. These two models were amalgamated to establish an integrated model for prediction of the oxygen blowing quantity. The average relative error of the integrated model is ,1%, and the hit rate of the integrated model is 97?14% when the relative errors of the model are within 5%.Relative to the multiple linear regression and the oxygen balance models, the integrated model may provide a more accurate prediction of the oxygen blowing quantity, and thus represents a good reference point for actual production.
BOF,, Oxygen blowing quantity,, Linear regression,, Oxygen balance,, Integrated model,, Relative error
-
126浏览
-
0点赞
-
0收藏
-
5分享
-
1129下载
-
0
-
引用
【期刊论文】Optimal control of secondary cooling for medium thickness slab continuous casting
刘青, X.-Y. Wang, Q. Liu*, B. Wang, X. Wang, J.-S. Qing, Z.-G. Hu and Y. H. Sun
Ironmaking and Steelmaking,-0001,():
-1年11月30日
A software to simulate the solidification, heat transfer and water flowrate distribution in slab continuous casting was developed by establishing a mathematical model for the heat transfer and solidification in medium thickness slab casting. This model was validated by pin shooting and surface temperature measurement experiments. A reasonable target surface control temperature was found by testing the high temperature mechanical properties of Nb bearing ship plate steel,and then the water flowrate of each loop of the secondary cooling zone was determined by the software. The influence of uneven secondary cooling in the slab width direction on the quality of the slab was also investigated, which provided data for the optimisation of the secondary cooling of the slab caster. On the basis of the above research, an optimisation scheme for a secondary cooling system was proposed. Experimental results showed that the quality of the slab was significantly improved after optimisation. The centreline macrosegregation was reduced, and the ratio of equiaxed grains was increased by 3?18%. In addition, the transverse cracking of the slab was almost eliminated.
Slab continuous casting,, Mathematical model,, Secondary cooling optimisation,, Ship plate steel
-